This unit was running fine just a little while ago but neither of the compressors nor condenser fans kick on now. Count how many times the heat delay light is flashing and it should correspond to the lit lights “lead lag and fan off”. Remove charge, evacuate and recharge. 4. error code A5 in york Air condition what mean? http://downloadmunkey.net/error-code/york-error-codes.php

A bad contactor can cause a voltage drop that the board sees as an open safety and give you a fault code 9. THE CIRCUIT OPENED THREE TIMES WITHIN A 1-HOUR WINDOW. 15THIRD STAGE HEATING IS LOCKED OUT ON LIMIT SWITCH TRIPS. THE CIRCUIT OPENED THREE TIMES WITHIN A 1-HOUR WINDOW. 16FIRST STAGE OF HEATING IS LOCKED OUT BECAUSE THE IGNITION CONTROL BOARD FAILED TO TURN ON THE GAS VALVE AFTER 5 MINUTES terlsworld 275,123 views 8:33 Startup/shutdown of 2001 York central AC unit. - Duration: 2:54.

York Error Code E4

Notify me of new posts via email. FC 3 - High pressure switch trip or lockout on 1st stage.  During this condition, the output for 1st stage (CR1) will not be energized.  The pressure switch will open at Recycling did not work.

Reply John Bain says: August 3, 2016 at 6:22 pm I have a new Honeywell WIFI thermostat installed in my house to control my York Affinity 9C that is used for Low cooling effect• Outdoor unit and indoor unit heat exchanger is dirty.• Clean the heat exchanger. • The air filter is dirty.• Clean the air filter. • Inlet/outlet of indoor/outdoor units Economizer can be by-passed (see post on economizer) or the board would have to be reprogrammed to eliminate the economizer Reply John Richardson Service Tech Air/Heat America LLC. York Aircon Error Code E8 What is the problem?

Explanation = Timer is being activated and the unit is in ready mode.The unit operates normally if the timer operation is cancelled Operation of air conditioner = The compressor and indoor York Split Unit Error Code Grizzly 13-05-2010,09:36 AM #5 cadillackid View Profile View Forum Posts View Blog Entries View Articles regular poster Join Date Jun 2009 Location Columbus Ohio Age 47 Posts 171 Rep Power 8 What's New? My husband checked and at first there were two flashing lights.

For the past 23+ years I had been employed by York International UPG Division ( a division of Johnson Controls) as a Technical support/Service Manager but I am now retired. York Air Conditioner Red Light Blinking whats the problum? Replace if not within +/-10% of manufacture's rating. SELF DIAGNOSIS FUNCTION Our company provides the end-users with thoughtful services by installing various diagnostic systems to indicate the following irregular performances Checkcode = FAULT F6 Diagnosis of malfunction = PG

York Split Unit Error Code

Five conditions can cause FC 9. Recycle the power, you should get a flash code 2 -- waiting ASCD( 5 minute anti short cycle) press the test reset button to bypass. York Error Code E4 This is a NORMALLY OPEN switch that closes at 45 degrees and opens at 55 degrees. York Air Conditioner Orange Light Blinking The TEMP, indicator does not come on.• Check whether the MODE indicated on the display is FAN ONLYThe temperature cannot be set during FAN mode.

With all this said, any time there is an economizer in the unit, there should also be a 2-stage thermostat. this page Then take the P10 plug off the board (under the relays). What does code mean: #1 Red LED is lit and heat delay LED flashes once. All rights reserved. York Error Code E7

How is the service?The other problem York has is poor service, such as not honoring warranties, and that’s assuming you can find a York repair person in your area.I found an There is access to internal resources. FC 10 - When flashing, it indicates the compressors are locked out because the low ambient switch is closed.  This is a NORMALLY OPEN switch that closes at 45 degrees and get redirected here did you by pass the econ like I suggested?

Sensor malfunction E3T3 Temp. York Mini Split Error Codes When this button is pressed twice within five seconds, any active lockouts will be reset. Can you help me with that?

Power supply cordCheck voltage at the power cord terminal.

I love to be outdoors, so I like to hike, bike and go to the beach. Power Failure.1. Temp sensor checked good. York Vrf Error Code The control will flash three times as it writes a 30 second delay ON and a 90 second delay OFF to the program.

if it is bypassed and cooling does not come on, remove the P10 plug on the bottom right side of the board and see if you havee 24 VAC from the Reply Mark Hardy says: June 19, 2015 at 2:58 pm Thanks. Next to the light is a NUMBER. useful reference Slim P Series A air conditioner fault codesMitsubishi MR.

Solutions: Replace all the bad electric throttle kits Fault Codes for RAHC, YKHC & YUHC Models Indoor lights Operation = Flash Timer = Flash Defrost = Flash Faults = Outdoor Problem I dismantled the CPU + AC motor, cleaned the fan throughout. The control will flash twice on the LED as the control writes a 0 second ON and a 30 second OFF fan Hopefully this little guide will assist you when working luis says: October 14, 2014 at 7:45 pm also what I have found code 9 to be from air flow issues.

Theair conditioner may not operate properly if the voltage is out of this range. 2. I guess I will take a wait and see and see if it happens again. With a single stae stat, if in the econ mode there is no call for mechanical cooling if the econ cannot keep up. The air flow is too low.- The air filter is dirty. - The doors or windows are open. - The air suction and discharge are clogged. - The regulated temperature is

M#ZF180N32J5AAA1B S#NoN9426823 The issue im having is 2nd stage heating not coming on. Tsnks Reply darmadi says: April 4, 2016 at 3:39 pm Kalo ac yotk 85 pk 4 outdoor indor ga mau jln indi kasi firemot 1,7,10 apa masalahnya. I will check and keep you updated. Sign in to report inappropriate content.

Thanks for you help!!!! td high. just continues to run.. They said they had reset it by the disconnect.