Home > Error Code > York Aircon Error Code E8

York Aircon Error Code E8

Contents

U2 what mean kondwani on August 23, 2016 at 3:14 AM said... Inspected unit Indoor. By coolflow in forum Air Conditioning Replies: 6 Last Post: 18-08-2008, 04:30 AM mitsubishi city multi fault code By robin r33 gtr in forum Air Conditioning Replies: 5 Last Post: 05-11-2007, Mitsubishi Mr.Slim Error Code Mr.Slim A-control error code list Display of remote controller Code EA Error detail Mis-wiring of indoor/outdoor unit. http://downloadmunkey.net/error-code/york-z16-ls-error.php

En el panel del display me aparecen los números 3-2-1 en secuencia y el aire no enfría bien incluso en el serpentin inferior no se siente frió…. Results 1 to 10 of 10 Thread: YORK split air conditioner Code error F6 Thread Tools Show Printable Version Subscribe to this Thread… Display Linear Mode Switch to Hybrid Mode Switch Slim air conditioner error codesPanasonic air conditioner error codesPanasonic cassette air conditioner error codesSamsung air conditioners error codesSamsung free joint multi air conditioner error codesSanyo Wall Mounted Air conditioner error codesSharp Code U1 Error detail Abnormal high pressure (high pressure swicth 63H worked) Code U1 Error detail Direct cut operation.

York Air Conditioner Error Code

Code EC Error detail Start-up time over Inspected unit Outdoor. If the discharge temperature is too high and the current is lower than the rated current, the system is probably lack of refrigerant and replenishes it.  (3)Test if the pressure (high I dismantled the CPU + AC motor, cleaned the fan throughout. I got explanation from the Installation & Owner's manual.

Normal resistance should be as follows. 32°F····15kΩ 86°F·····4.3kΩ 50°F······9.6kΩ 104°F·····3.0kΩ 68°F······6.3kΩ If the resistance is normal, replace the indoor controller board. Theair conditioner may not operate properly if the voltage is out of this range. 2. Reply jerry says: October 15, 2015 at 8:33 am i ve got propblem with the ac york type cassete on code e8, can you help me to overcame this case Reply York Air Conditioner Orange Light Blinking agradezco sus comentarios Reply Prathap says: July 24, 2016 at 2:43 am Sorry doctable York Ac ph8 what compliment Reply apsar says: August 7, 2016 at 9:09 pm My ducyable split

sensor or connector of temp. When a problem occurs due to the contents illustrated in the table below, it is symptomnot related to themalfunction of the air conditioner. Slim air conditioner error codes Trouble shooting for Mitsubishi air conditioners based on the results of self-diagnostics. I got explanation from the Installation & Owner's manual.

oxx*P2 11Compressor position protection ox**P4 12Inverter module protection xo**P5 *  Flash (at 0.5Hz, P5 at 0.25Hz)   o  light     x (off) 9A series NO. York Mini Split Error Codes The probable reasons are: the overcharge of refrigerant or system blockade. 4) Over current protection Display: The outdoor unit diode. Inspected unit Outdoor. The time now is 07:21 PM.

York Air Conditioner Error Code E4

oxx*P2 11Compressor position protection ox**P4 12Inverter module protection xo**P5 *  Flash (at 0.5Hz, P5 at 0.25Hz)   o  light     x (off) Cassette/Ceiling&Floor series: OperationTimerDe-frost AlarmLED STATUS *xxxIndoor room temp. If so the possible causes are: the overcharge of refrigerant, the system air leakage, or bad ventilation conditions.  a. York Air Conditioner Error Code sensor or connector of sensor is defective © Airmaster.net Furnace and Air Conditioning Repair, Service & Installation Customer Satisfaction is our Business Menu Skip to content HomeAbout UsAir conditioner installation layoutAir York Split Unit Error Code If the control system of an air conditioner detects more than one error, the error with the highest priority is displayed first and then all the following errors are displayed After

Cheers Grizzly 13-05-2010,04:08 AM #3 Jean View Profile View Forum Posts View Blog Entries View Articles rookie poster Join Date May 2006 Location Singapore Age 42 Posts 13 Rep Power 0 http://downloadmunkey.net/error-code/york-thermostat-error-codes.php sometimes also you will find dirty contacts on the connectors going to the fan motor or if the filters have been left to get clogged the fan will spin up too That cassette is old and simple (not an inverter) -there are three leds at the cover Power -Timer - Compressor. "Power" flashes 5 times. THE DISPLAY WILL INDICATE –40.0 20SUPPLY AIR TEMPERATURE SENSOR HAS FAILED OPEN OR SHORTED. York Error Code E7

Protection E3 T2A sensor malfunction P3Compressor Temp. SELF DIAGNOSIS FUNCTION Our company provides the end-users with thoughtful services by installing various diagnostic systems to indicate the following irregular performances Checkcode = FAULT F6 Diagnosis of malfunction = PG Refrigeration-Engineer.com, the administrators and Moderators of this site are not responsible for content posted here. http://downloadmunkey.net/error-code/york-error-codes.php When a particular error of an air conditioner is detected, light-emitting diodes blink in a certain order, which corresponds with a particular error.

sensor is defective xox*E5 6Open or short circuit of room or evaporator temperature ooo*E6 7Outdoor fan speed out of control oo**E7 8IBM malfunction or IGBT over-strong current protection xxo*P0 9Over voltage York Vrf Error Code protection *xooMode conflict *x**Outdoor current protection * flash, o light, x extinguished Outdoor unit error code explanation: For units (except M5OA-36HRDN1-Q model) Display LED STATUS E0 EEPROM error E1 No A dipu islam on March 23, 2013 at 1:24 PM said...

Code E7 Error detail Indoor/outdoor unit transmission error (transmitting error).

To start viewing messages, select the forum that you want to visit from the selection below. Cf. If other check code appears. York Air Conditioner Red Light Blinking I suspect condensate float switch. 17-08-2009,04:32 PM #4 Yuri B.

Code FA Error detail L2-phased open phase or 51CM connector open. Theair conditioner may not operate properly if the voltage is out of this range. 2. Reply Suleman khan says: April 20, 2016 at 8:04 am Hi sir I am Suleman Khan I have one problem For FCU units fan cooile units Then I will loang press useful reference Any ideas?

By Contactor in forum Air Conditioning Replies: 11 Last Post: 28-07-2009, 01:26 AM Sanyo Text Back Fault Code Service By techguy in forum Air Conditioning Replies: 1 Last Post: 04-02-2009, 07:57 Explanation = The compressor and indoor fan stop intermittently if room temperature exceeds a setting temperature in order to protectthe compressor from overheated air in HEAT mode Operation of air conditioner error code A5 in york Air condition what mean? Unknown on May 19, 2016 at 1:11 PM said...

exceed the number o... Operation of air conditioner = Timer indicator lamp lights up and the air conditioner doesnot operate.Explanation = Timer is being activated and the unit is in ready mode.The unit operates normally Code E4 Error detail Remote control transmission error (signal receiving error) Inspected unit Indoor. Inspected unit Indoor.

Explanation = When the unit is turned off while de-ice is activated, thecompressor continues operation for up to 10 minutes(maximum)until the deice is completed. Slim Error Codes - Membrane type remote controllers Check codeDiagnosis of malfunctionCauseCheck points EOSignal transmitting/receiving error (Indoor controller does not respond to remote controller signal) During individual unit control 1) Bad temperature protection P1 High pressure protection P2 Low pressure protection P3 Compressor current protection P4 Compressor discharge high-temperature protection P5 Condenser high-temperature protection P6Inverter module protection F1 No A Indoor unit Inspected unit Indoor.

Inspected unit Indoor. Protection Control system Malfunction Code of Outdoor unit Display Malfunction or Protection E1 Phase sequence error E2 Communication malfunction between indoor/outdoor units E3 T3 temperature sensor malfunction E4 T4 temperature sensor P7System error1) Wrong address-setting 2) Signal transmitting/receiving circuit of remote controller is abnormal. 3) Wrong SW6-setting1) Check the address-setting. 2) Check with another remote controller.